Horizontal Stainless Steel Chemical Centrifugal Pump for Filter Press

Flow rate Q: 6.3~400m3/h
Lift H: 5~132m
Speed n: 2900, 1450r/min
Belt power: 0.55~110KW
Import diameter: 50~200mm
High working pressure: 1.6Mpa

Product Details

Introduction of Chemical Centrifugal Pump for Filter Press

The IH-type stainless steel chemical centrifugal pump, often integrated with filter press systems, is a single-stage, single-suction cantilever design. It’s an energy-efficient alternative to the F-type corrosion-resistant pump. This pump series, ideal for filter press operations, is crafted based on the performance criteria, technical specifications, and testing methods of energy-saving pumps. It’s among the energy-saving pump products endorsed in our country.
Especially in filter press applications, where clean water and other liquids with properties akin to water need to be transferred without solid particles, this pump proves invaluable. It’s extensively used in sectors like urban industrial and agricultural drainage, fire water supply, and for conveying corrosive media at 20°C to 105°C or media with physical and chemical properties similar to water.

Stainless Steel Chemical Centrifugal Pump

Horizontal Stainless Steel Chemical Centrifugal Pump Model Meaning

For example: IH80-65-60A
A: The outer diameter of the impeller is cut for the first time
160: Impeller nominal diameter (mm)
65: Discharge port diameter (mm)
80: Suction port diameter (mm)
IH: International standard chemical centrifugal pump

Product Parameter

ModelRotating speedFlow (m3/h)Flow(L/S)Lift(m)Efficiency(%)Shaft power(Kw)Equipped power (Kw)NPSH (m)Weight(kg)
IH50-32-125290012.53.4720511.332.2245
IH50-32-16012.53.4732462.373249
IH50-32-20012.53.4750394.365.5259
IH50-32-25012.53.4780338.2511293
IH65-50-125251.532622.23247
IH65-50-160252.7832573.825.5253
IH65-40-200252.9250526.5511263
IH65-40-250252.9280464615299
IH65-40-315253.061253939302116
IH80-65-1255013.920693.955.5352
IH80-65-1605013.932676.5112.357
IH80-50-2005013.9506310.8152.565
IH80-50-2505013.9805818.8302.5103
IH80-50-3155013.91255232.73452121
IH100-80-12510027.820737.47114.557
IH100-80-16010027.8327311.9154.387
IH100-65-20010027.8507218.9303.996
IH100-65-25010027.8806832453.6115

Please consult us for more models

Filter Press Chemical Centrifugal Pump Features

The IH-type stainless steel chemical centrifugal pump boasts a logical design and dependable hydraulic performance. It’s compact, lightweight, and offers excellent resistance to cavitation, consuming minimal power. This pump is user-friendly, easy to maintain, and operates efficiently. The IH single-stage, single-suction centrifugal pump features a horizontal design, aligning well with the needs of most pipeline installations.

Conditions of Use

The IH stainless steel chemical pump has a maximum operational pressure of 1.6 MPa. The medium’s temperature must not exceed 80℃. If required, a dual-end seal cooling mechanism can be utilized, allowing for the transportation of mediums with temperatures ranging from 20°C to +280°C.
Note: Users can choose different materials for the main parts of the flow-passing part of the pump according to the corrosiveness of the medium being transported.

Installation Dimension Drawing

chemical centrifugal pump installation dimension drawing

ModelMotor model power(Kw)Shape and installation dimensions
AL1L2L3L4afXL5B2B3B4/B5h1h2/h2'h3HH1H2n-d
IH50-32-125YB801-4/0.5582015054033080385100895360320150/225112170/325251973174424-φ19
YB802-2/1.1
YB90S-2/1.580360925155/225190/340
IH65-50-125YB801-4/0.558082015054033080385100895360320150/225112170/325251973374424-φ19
YB802-4/0.75
YB90L-2/2.2920170600385950390350155/225190/34030447
IH65-40-200YB802-4/0.7580920170600330100385100915390350150/225160170/325302454254904-φ19
YB90S-4/1.1360945155/225190/340495
YB90L-4/1.5385970

Installation Order

1. Position the unit on the foundation using embedded anchor bolts. For alignment, insert wedge pads between the base and the foundation.
2. Detach the coupling. Position a level on the pump shaft or base as needed. Adjust the leveling pad to ensure the unit is level, then secure the anchor bolts to prevent any shifts.
3. Fill the base and anchor bolt inspection holes with concrete.
4. Once the concrete has been set, tighten the anchor bolts and re-examine the pump shaft for smooth operation.
5. After attaching the pipeline and confirming the prime mover’s rotation direction, reconnect the coupling. Reassess the shaft’s concentricity and measure the top and bottom of the coupling’s outer circle. The discrepancy between the left and right should not surpass 0.1mm. For the end face gap, the largest and smallest gap difference within a week shouldn’t exceed 0.3mm.
6. After the unit has run for 3 to 4 hours, perform a final check. If no issues arise, the installation is considered successful.